Range: 5-50V, default: 15.
BRAKE_EN: Motor reverse brake enable control.
0: disable motor brake.
1 : enable brake.
Default: 1.
AUTO_AMPAuto amplification value.
This parameter defines the sensitivity to the arc voltage
deviation. If this value is set too high, the lifter
positioning during auto height control will become
unstable and prone to oscillation. If this value is set too
low, the lifter positioning during auto height control will
become slow and inaccurate.
Range:1-20default10
UP_BRK_T: Upward move brake time.
This parameter defines the reverse brake time of the
lifting motor after an upward movement.
Unit: ms (millisecond)
Range: 0-100, default: 20.
DN_BRK_T: This parameter defines the reverse brake time
of the lifting motor after a downward movement.
Unit: ms (millisecond)