torch nozzle during cutting. The intelligent arc voltage
adjustment function make it possible to cut the left part
of an whole job without collision temporally, but the user
should check the cutting torch immediately after current
job.
Range:5-50V, default:10.
ADJ_STEPArc voltage intelligent adjustment step.
This parameter defines the step value of arc voltage
while intelligent arc voltage adjustment occurs.
Range: 1-5V, default: 1.
INTEL_SG Arc voltage intelligent adjustment enable control.
0: disable this function.
1: enable this function.
default: 0.
ARC_ACCUArc voltage accuracy.
This parameter defines the arc voltage accuracy while
auto height control.
Range: 1-10V, default: 1V.
PIER_ENPierce enable control.
This parameter enables or disables the pierce function
of the controller.