0: Disable the pierce procedure.
1: Enable the pierce procedure.
default: 1.
FAIL_LFT: Torch lifting time after arc off.
Unit0.1second.
0: Disable torch lifting after arc off.
Range: 0-100, default: 10.
COL_STOP: Torch collision stop enable control.
Range: 0-1, default: 0.
0: Disable this function.
1: Enable this function.
If a certain number of continued collisions have been
detected, the controller will stop the plasma power and
disable the MOTION signal to the CNC system.
DELAY_INArc voltage delayed input time.
This parameter defines the time to be delayed from
starting arc to the arc voltage input to the controller
through the isolated relay. It is used to avoid the HV and
HF interferences from the plasma power while starting
arc.
Unit: 0.1 second.