- 25 -
optek-sensors AS56, Version 04.2010_1.2US, 15.04.2010
www.optek.com
Connection to converter C4000
Note!
Do not use other detector inputs and lamp outputs than given in table 9, even if
in some cases other combinations are possible. Thus, danger of mixing inputs
and outputs up is minimized.
Tab. 9 Connections
Number of
sensors
Sensor type
Detector input connection of the
converters
Lamp
output
Cable set standard
length up to
C4101
C4121
C4151
C4201
C4221
C4251
C4202
C4222
C4252
C4322
C4352
C4422
C4452
1 sensor
AS56
A
A
A
A
A
E
50 m / 164 ft.
2 sensors
AS56
AS56
A
C
A
C
A
C
E
E or F
50 m / 164 ft.
2 sensors
AF16
AS56
A
C
A
C
A
C
E
F
100 m / 328 ft.
*
50 m / 164 ft.
*. Cable sets length > 100 m (328 ft.) on request.
2 sensors
AS16 / AS16-BT
AS56
A
C
A
C
A
C
E
F
50 m / 164 ft.
2 sensors
AF26
AS56
A / C
B
A / C
B
E
F
100 m / 328 ft.*
50 m / 164 ft.
2 sensors
AF45
AS56
A / C
B
A / C
B
E
F
100 m / 328 ft.
50 m / 164 ft.
2 sensors
TF16
AS56
A / C
B
A / C
B
E
F
100 m / 328 ft.
50 m / 164 ft.
3 sensors
2 x AS56
AS56
A / C
B
A / C
B
E
F
50 m / 164 ft.
3 sensors
2 x AS56
AF16
A / C
B
A / C
B
E
F
50 m / 164 ft.
100 m / 328 ft.
3 sensors
2 x AS56
AS16 / AS16-BT
A / C
B
A / C
B
E
F
50 m / 164 ft.
3 sensors
2 x AS56
AF26
A / C
B / D
E
F
50 m / 164 ft.
100 m / 328 ft.*
3 sensors
2 x AS56
AF45
A / C
B / D
E
F
50 m / 164 ft.
100 m / 328 ft.
3 sensors
2 x AS56
TF16
A / C
B / D
E
F
50 m / 164 ft.
100 m / 328 ft.*
4 sensors
2 x AS56
2 x AS56
A / C
B / D
E
F
50 m / 164 ft.

Related product manuals