Slide the ller into the vacant slot until the front of the ller is ush with the front of the server.
Close the latch and rotate the release lever to lock the latch.
■
“How to Remove a Hard Drive Filler” on page 48
■
“How To Remove a Removable Hard Drive Assembly” on page 50
■
“How to Install a Removable Hard Drive Assembly” on page 51
▼
HowTo Remove a Removable Hard Drive Assembly
Caution – Thermal over-temperature potential. Do not operate the server without all drive slots
populated with either a drive or a ller panel.
Power o the server. See “How to Power O the Server”on page 28.
Note – If you are using an integrated-mirroring (IM) conguration, you do not need to power o
the server before removing a hard drive.
On the drive you want to remove, push the release button to open the latch and extend the latch
to its fully-open position.
Note – The latch is not an ejector. Do not bend it too far to the right. Doing so may damage the
latch.
3
4
See Also
1
2
Removing and Installing a Hard Drive Filler and Hard Drive Assembly (CRU)
Sun Fire X2270 M2 Server Service Manual • January, 2012, –1250