To restore FRUID information, enter Service mode and type the following command:
copypsnc BACKUP1 PRIMARY
The MAC address stored in BACKUP1 is incorrect, because it is the address for the old MB.
To obtain the MAC address of the new motherboard, log in to the ILOM CLI and enter the
following command:
show /SYS/MB/NET0
The MAC address appears in the list.
Make note of the MAC address.
In Service mode, type the following command:
setpsnc -m new-mac_address
where, new-mac_address is the MAC address of the new motherboard.
Backup the MB FRUID information. See
“How to Backup Motherboard FRUID Informationon
page 78
.
Prepare the server for operation. See
“How to Prepare for Operationon page 26.
13
14
15
16
17
18
Replacing the Motherboard (FRU)