Type of error detected
When or where the error occurred
The following table lists some of the F1 and F2 error messages that could appear during the
POST diagnostics and instructions for how to possibly resolve the error reported.
BIOS POST Error Message ErrorType Resolution
Uncorrectable Error Detected on Last Boot:IOH(0) Protocol
Error (Please Check SP Log for more Details)
IOH error
Press F1 to continue.
Check the SP event log in ILOM for more details.
Uncorrectable Error Detected on Last Boot:IOH(0) QPI [x]
Error (Please Check SP Log for more Details)
Note Where QPI [ x] equals 0 for QPI Link 0 or 1 for QPI
Link 1.
IOH error
Press F1 to continue.
Check the fault management function and the SP
event log in ILOM for more details.
Uncorrectable Error Detected on Last Boot:IOH(0) PCIe [x]
Error (Please Check SP Log for more Details)
Note Where PCIe [ x] port number can range from 1 to 10
depending on the PCI root port on IOH.
IOH error
Press F1 to continue.
Check the fault management function and the SP
event log in ILOM for more details.
Uncorrectable Error Detected on Last Boot:IOH(0) ESI Error
(Please Check SP Log for more Details)
IOH error
Press F1 to continue.
Check the fault management function and the SP
event log in ILOM for more details.
Uncorrectable Error Detected on Last Boot:IOH(0) Thermal
Error (Please Check SP Log for more Details)
IOH error
Press F1 to continue.
Check the fault management function and the SP
event log in ILOM for more details.
Uncorrectable Error Detected on Last Boot:IOH(0) DMA
Error (Please Check SP Log for more Details)
IOH error
Press F1 to continue.
Check the SP event log for more details.
Uncorrectable Error Detected on Last Boot:IOH(0)
Miscellaneous Error (Please Check SP Log for more Details)
IOH error
Press F1 to continue.
Check the fault management function and the SP
event log in ILOM for more details.
Uncorrectable Error Detected on Last Boot:IOH(0) VT-d
Error (Please Check SP Log for more Details)
IOH error
Press F1 to continue.
Check the SP event log in ILOM for more details.
BMC Not Responding ILOM error
Press F1 to continue.
Note This error message might appear if an
internal error occurs during the SP/BIOS
communication. This error might require you to
restart the SP.
BIOS POST F1 and F2 Errors
85

Other manuals for Oracle Sun Fire X2270 M2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle Sun Fire X2270 M2 and is the answer not in the manual?

Oracle Sun Fire X2270 M2 Specifications

General IconGeneral
BrandOracle
ModelSun Fire X2270 M2
CategoryServer
LanguageEnglish

Related product manuals