1-4 Introduction
Subcarrier inputs sum into the composite baseband outputs before the digitally controlled composite attenuators.
The sensitivity of the both SCA inputs are variable from 220 mV p-p to >10 V p-p to produce 10% injection. Internal
PC-board-mounted trim pots determine the sensitivity.
The correct peak level of the stereo program applied to the stereo encoder sometimes depends on the number of
subcarriers in use. Some regulatory authorities require the total baseband peak modulation to be maintained
within specified limits. Thus, the level of the stereo main and subchannel must be reduced when a subcarrier is
turned on. The 5950’s remote control feature allows you to reduce the stereo main and subchannel level by
connecting an on/off signal from your subcarrier generator. You define the amount of reduction (in units of
percent modulation) on the Input/output screen. See page 2-62 for information on programming the remote
control. A jumper on the circuit board can reconfigure the SCA 2 input to provide the stereo pilot tone only, which
can provide a pilot reference for an RDS subcarrier generator.
Digitized Subcarrier Inputs
Two additional subcarrier inputs are provided on the rear panel. These are digitized and are summed only into the
digital composite output. Their mix level is set in the Input/Output 5 screen titled Composite 2. At the PC remote,
they are located in the I/O SETUP SCREEN with the tab DIGITAL ENCODER. If you need to use both the digital and
analog composite outputs, you must split the outputs of your SCA generators with Y cables so that each generator
output drives one digitized SCA input and one non-digitized SCA input.
Wordclock/10 MHz Sync Reference Input
The sync reference input (labeled REF IN) appears on a female BNC jack on the rear panel. It is available only on
MPX hardware. It accepts a 1x 5V p-p squarewave wordclock signal at 32, 44.1, 48, 88.2, or 96kHz, or a 10MHz
sinewave or squarewave signal, 0.5 to 5V peak. 10MHz is a common output frequency produced by GPS and
rubidium frequency standards. You can configure the 5950 to lock its 19kHz pilot tone and output sample
frequency to this input. When a valid reference signal is applied to this input, it locks the OPTIMOD’s Internal DSP
clock to this input, so if a given AES3 L/R output’s sync source is set to INTERNAL, the sample frequency at that
output will be locked to this reference signal.
Do not apply an AES3 signal to this input.
Remote Control Interface
The Remote Control Interface is a set of eight optically isolated inputs on a DB-25 connector that can be activated
by 5-12V DC. They can control various functions of the 5950.
Computer Interface
On the rear panel of the 5950 are serial ports and Ethernet ports. These computer interfaces support remote
control and metering, downloading software upgrades, and audio-over-IP connectivity. Each 5950 can be accessed
via a web browser using the IP address configured on the 5950.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Orban OPTIMOD 5950 and is the answer not in the manual?

Orban OPTIMOD 5950 Specifications

General IconGeneral
BrandOrban
ModelOPTIMOD 5950
CategoryComputer Hardware
LanguageEnglish

Related product manuals