Orban 5950 Technical Manual Operation 3-33
AF 20=0
AF 21=0
AF 22=0
AF 23=0
AF 24=0
Security
In the System I/O RDS control screen, you can set the RDS Terminal control security by specifying an RDS IP address
from which to accept commands. Once set, this IP will be the only IP that can connect to the unit to update RDS.
The 5950 will default to 0.0.0.0, which will allow any IP to connect to the RDS terminal control.
To prevent the OPTIMOD from disconnecting and being unable to reconnect if the terminal connection
drops out temporarily, set the TIMEOUT value to the maximum expected duration of the dropout (in
minutes). Default is 4 minutes. Note that the timeout reverts to the default each new connection; if you
change the timeout for one connection, it is not retained for the next one.
RDS Terminal Commands
lists the terminal commands.
Note that you can fetch the status of the RDS generator as follows:
>FRPPDQG@"UHWXUQVFXUUHQWYDOXH
67UHWXUQVFXUUHQWYDOXHRIDOOFRQWUROV
+(/3UHWXUQVDOLVWRIWKH5'6WHUPLQDOFRPPDQGV
= CR/LF
incoming DPS and transmission of DPS Default. Default
is the DPS control value as designated in the I/O Setup.
incoming DPS and transmission of DPS Default. Default
is the DPS control value as designated in the I/O Setup.