ST 6100 - HARDWARE GUIDE
Parameter Description
Exposure to Chemicals
and Oils
The terminal meets all of its specifications after a light to moderate splash test as detailed in SAE
J1455 section 4.4.3.2, for the following chemicals:
Window Washer Solvent
Gasoline
Diesel Fuel
Fuel Additives
Alcohol
Antifreeze Water Mixture
Degreasers
Soap and Detergents
Steam
Waxes
Kerosene
Freon
Spray Paint
Paint Strippers
Ether
Dust Control Agents (magnesium chloride)
Moisture Control Agents (calcium chloride)
Ammonia
Aluminum brightener (acid wash)
Steam Cleaning and
Pressure Washing
The terminal meets all of its specifications after a steam cleaning and pressure wash test as
detailed in SAE J1455, section 4.5.3.
Fungus The terminal meets all of its specifications after a fungus test as detailed in SAE J1455, section
4.6.3.
Dust and Sand
Bombardment
The terminal meets all of its specifications after a dust and sand bombardment test as detailed in
SAE J1455, section 4.7.3.
The terminal meets the acceptance conditions of IEC 60529, section 13.6.2 after a dust and sand
bombardment test as detailed in IEC 60529, section 13.4.
Drop Test The terminal meets all its specifications after a handling drop test as specified in SAE J1455,
section 4.11.3.1.
ESD The terminal shall meet all its specifications after exposure of the enclosure to
15 kV ESD air discharge per IEC 60945 and IEC61000--4-2, level 4.
T406, VERSION 01
30
© ORBCOMM PROPRIETARY