EasyManua.ls Logo

Otto Bock Discovery - Foreword; Contraindications; Indications; Indications for Use

Otto Bock Discovery
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1 Foreword
INFORMATION
Last update: 2018-01-26
Please read this document carefully before using the product.
Follow the safety instructions to avoid injuries and damage to the product.
Instruct the user in the proper and safe use of the product.
Please keep this document in a safe place.
INFORMATION
New information regarding product safety and product recalls can be obtained from the Customer Care Cen
ter (CCC) at oa@ottobock.com or from the manufacturer’s service department (see inside back cover or back
page for addresses).
You can request this document as a PDF file from the Customer Care Center (CCC) at oa@ottobock.com or
from the manufacturer’s service department (see inside back cover or back page for addresses). It is possible
to increase the display size of the PDF document.
Initial adjustments to the product were made according to the order form. Nevertheless, fine adjustment may be
required and settings may have to be made according to the medical conditions or the user's requirements.
These instructions for use provide the information necessary for adjusting the settings. This work should be closely
coordinated with the user.
Please note the following:
The instructions for use (qualified personnel) are intended only for qualified personnel and remain with them.
The operation of the product and functionality of the options are described in the instructions for use (user).
These instructions for use must be given to the user.
All users must be instructed in the use of the product by you or an attendant using the instructions for use
(user).
The manufacturer recommends checking the product settings regularly in order to assure an optimum fit over
the long term. A review is required every six months for children and youths in particular.
The installation and retrofitting of all optional components are generally described in the service manual.
2 Intended use
2.1 Indications for use
The Discovery mobility base for seating shells is intended exclusively for the adaptation of orthopaedic seating sys
tems (e.g.seating shells) for people who are unable to walk or have walking impediments. It can be operated
either by the user or by an attendant. The product can be used indoors and outdoors.
The Discovery mobility base for seating shells was developed especially for the adaptation of modular seating sys
tems. It is fully adjustable to provide for individual adaptation to the needs of the user.
The product may only be used with the options which are listed in the product order form.
Ottobock assumes no liability for combinations with medical devices and/or accessories from other manufacturers
not included in the modular system.
2.2 Indications
The product can be used for a disability or walking impairment, for example due to:
Paralysis (paraplegia, tetraplegia)
Loss of limbs (leg amputation)
Defects or deformation of the limbs
Joint contractures or damage
Neurological and muscular diseases
2.3 Contraindications
Not known.
2.4 Qualification
The adjustment tasks described below are necessary for optimum adaptation to the respective seating system, and
may only be completed by qualified, authorised personnel.
5Discovery
Foreword

Table of Contents

Other manuals for Otto Bock Discovery

Related product manuals