12.3 Thermal Requirements
Thermal requirements specific to Rev A and Rev B OS1 are listed below. Please contact sup-
port@ouster.ioor withyoursensor serialnumber ifyoudonot knowwhat Revyoursensor is.
Table 12.1: Thermal requirementsforGen2OS1 withmodular cap
Requirements ExampleTest Case
Base Enclosure
Temp (ºC)
Top Modular
CapTemp (ºC)
ConvectiveAirTempwith
RadialHeatsinkandStan-
dardBase(ºC)
Max Temp before Shot
LimitingOccurs
52 52 47
Max Temp before Sensor
ShutsOff
65 65 60
13 ElectricalInterface
13.1 InterfaceBox
The Interface Box that accompanies the OS1 is designed to allow the sensor to be operated for test
and evaluation purposes. It terminates the interface cable from the sensor, allows it to be powered
up and provides access to the sensor gigabit Ethernet Interface via a standard RJ45 connector. DC
Powertothe sensorisprovidedtothe InterfaceBox bytheaccompanying24VDC supply.