3.Functions and Operations
2. Connect the test lead.
Forward Bias
I
3. Set the beeper.
Press the Beeper softkey to enable or disable the beeper. When the beeper is
enabled, the diode is connected, the multimeter will beep continuously.
4. Diode measurements behave as follows:
Forward pressure
drop of diode
Display and beep
0 to 3 V
Displays measured voltage, and the multimeter beeps
when the voltage is below 0.7 V (if beeper enabled)
> 3 V Displays "Open" with no beep
Measuring Capacitance
This section describes how to configure capacitance measurements.
Operating Steps:
1. Enable the capacitance measurement.
Press on the front panel to enter capacitance measurement mode.