24
ERR 10 Current Alarm
Current value over the set point of 1A for a time
longer than 100 ms in phase 1 or
Current value over 8,12A for a time longer than 100
ms in phase 2 or
Current value over the set point of 1A for a time
longer than 100 ms in phase 3
Voltage value over 70V in buffer for a time longer
than 1 s
Current value over 2 A for a time longer than 2 s
Failure batteries
Failure of battery charger
Problems with electronic card of control
ERR 11 Processor Error No signal from Hall Sensor
Wrong wiring of Hall Sensor on the motor or
break of wiring
Break of Hall Sensor
Problems with electronic card of control
ERR 12 Tuned of motor Wrong sequence of configuration of Hall Sensor
Wrong wiring of Hall Sensor on the motor or
break of wiring
Break of Hall Sensor
Problems with electronic card of control
ERR 14
Overtime of
battery charger
Active when the recharge time exceeds the time limit
Failure of the batteries
Problems with electronic card of control
ERR 15 Overload
Alarm of the service circuit turns on when battery
charger works
Intervention time 3 s
Lighting service circuit (light,direction lights...)
When battery charger works
Problems with electronic card of control
ERR 16
Over
temperature of
battery charger
Excessive overheating of the battery charger
(environmental
condition, break of the batteries)
Problems with electronic card of control