PEC017
5/3/2018 Page 94 of 105
N087
Page 56
Min
Default
Max
PTO Mode Preset Engine Speed (In-
Cab)
0
780
2000
* To Enable, Engine Speed Capture or Engine Speed Preset w/ Set Switch (N110)
must be PRESET (0)
N088
Page 58
Min
Default
Max
Remote PTO in Vehicle Parked
State
OFF (0)
ON (1)
ON (1)
N089
Page 54
Min
Default
Max
Neutral Required for PTO Mode
OFF (0)
ON (1)
ON (1)
* Recommended to be disabled with Eaton Ultrashift transmissions
N090
Page 56
Min
Default
Max
Engine Speed Decrease
w/Res/Decel (Remote)
10
50
1000
N091
Page 56
Min
Default
Max
Engine Speed Ramp-down
w/Res/Decel (Remote)
10
250
1000
N092
Page 56
Min
Default
Max
Engine Speed Increase w/Set/Accel
(Remote)
10
50
1000
N093
Page 56
Min
Default
Max
Engine Speed Ramp-Up w/Set/Accel
(Remote)
10
250
1000
N101
Page 54
Min
Default
Max
Disable PTO Mode w/ Brake
Depressed
OFF (0)
ON (1)
ON (1)
* Required for Mobile Cab Station w/ Accelerator and Switches configurations
* Required if PTO Mode Vehicle Speed Limit (N080) is greater than 3 MPH