123
Heating Characteristic
[Condition] Room temperature: 70.0°F (21.1°C) (DBT), 60.0°F (15.6°C) (WBT)
Operation condition: High fan speed
Piping Length: 7.5m (24.6 ft)
230V 60Hz
B) Indoor unit capacity: Heating (2.0 + 3.2: CS-ME7RKUA + CS-E12RKUAW), service mode frequency = 64Hz
Gas Side Piping
Pressure (PSI (MPa))
Current
(A)
Outlet Air
(°F (°C))
Outdoor Air Temperature F C))
5
(-15.0)
10
(-12.2)
15
(-9.4)
20
(-6.6)
25
(-3.8)
30
(-1.1)
35
(1.6)
40
(4.4)
45
(7.2)
50
(10.0)
55
(12.7)
60
(15.5)
65
(18.3)
70
(21.1)
75
(23.8)
80
(26.6)
80.0 (26.6)
85.0 (29.4)
90.0 (32.2)
95.0 (35.0)
100.0 (37.7)
105.0 (40.5)
110.0 (43.3)
8.000
8.500
9.000
9.500
10.000
10.500
11.000
11.500
12.000
12.500
250.000 (1.723)
300.000 (2.068)
350.000 (2.413)
400.000 (2.757)
450.000 (3.102)
ME7RKUA
E12RKUAW
Outdoor Air Temperature F C))
5
(-15.0)
10
(-12.2)
15
(-9.4)
20
(-6.6)
25
(-3.8)
30
(-1.1)
35
(1.6)
40
(4.4)
45
(7.2)
50
(10.0)
55
(12.7)
60
(15.5)
65
(18.3)
70
(21.1)
75
(23.8)
80
(26.6)
Outdoor Air Temperature F C))
5
(-15.0)
10
(-12.2)
15
(-9.4)
20
(-6.6)
25
(-3.8)
30
(-1.1)
35
(1.6)
40
(4.4)
45
(7.2)
50
(10.0)
55
(12.7)
60
(15.5)
65
(18.3)
70
(21.1)
75
(23.8)
80
(26.6)