Item Unit OUTDOOR UNIT
Dry Bulb Wet Bulb
Indoor Operation Range
Cooling
Maximum °C (°F) 32 (89.6) 23 (73.4)
Minimum °C (°F) 16 (60.8) 11 (51.8)
Heating
Maximum °C (°F) 30 (86.0)
Minimum °C (°F) 16 (60.8)
Outdoor Operation Range
Cooling
Maximum °C (°F) 46 (114.8) 26 (78.8)
Minimum °C (°F) -10 (14.0)
Heating
Maximum °C (°F) 24 (75.2) 18 (64.4)
Minimum °C (°F) -15 (5.0) -16 (3.2)
Multi Indoor
RPM
CS-ME5RKUA CS-ME7RKUA CS-E9RKUAW CS-E12RKUAW CS-E18RKUAW CS-E24RKUAW
Mode
Fan
Tap
rpm
Airflow
(m
3
/min)
rpm
Airflow
(m
3
/min)
rpm
Airflow
(m
3
/min)
rpm
Airflow
(m
3
/min)
rpm
Airflow
(m
3
/min)
rpm
Airflow
(m
3
/min)
COOL
SHi 1080 11.71 1110 12.10 1140 12.21 1280 13.35 1370 18.96 1460 19.94
Hi 990 10.70 1020 11.10 1050 11.20 1160 12.00 1330 18.40 1350 18.40
Me 820 8.80 840 9.08 850 8.96 940 9.54 1160 16.03 1180 16.03
Lo 660 7.00 660 7.06 660 6.83 720 7.08 990 13.65 1020 13.79
Lo- 570 6.00 570 6.06 570 5.83 580 5.51 900 12.40 930 12.54
HEAT
SSHi 1210 12.70 1240 13.11 1270 13.21 1370 14.29 1460 20.46 1500 20.35
SHi 1120 11.70 1150 12.10 1180 12.20 1300 13.50 1370 19.20 1460 19.80
Me 950 9.79 960 9.97 980 9.96 1140 11.71 1210 16.97 1310 17.70
Lo 780 7.89 780 7.96 780 7.72 980 9.92 1060 14.87 1160 15.61
Lo- 690 6.88 690 6.95 690 6.71 890 8.91 960 13.48 1050 14.07
Note
Specifications are subject to change without notice for further improvement.