1-14-3
1
Information requirements for air-to-air air conditioners Information requirements for heat pumps
Model(s): Outdoor Unit Model(s): Outdoor Unit
Indoor Unit Indoor Unit
Outdoor side heat exchanger of air conditioner: Outdoor side heat exchanger of heat pump:
Indoor side heat exchanger of air conditioner: Indoor side heat exchanger of heat pump:
Type: compressor driven vapour compression or sorption process Indication if the heater is equipped with a supplementary heater:
Item Symbol Value Unit Item Symbol Value Unit Item Symbol Value Unit Item Symbol Value Unit
Rated cooling capacity Prated,c 20.0 kW
Seasonal space
cooling energy efficiency
η
s,c 326.2 % Rated heating capacity Prated,h 22.4 kW
Seasonal space heating
energy efficiency
ηs,h
182.2 %
Refrigeration load P
design,c 20.0 kW Refrigeration load Pdesign,h 18.0 kW
Tj= + 35 ºC 20.0 kW
Tj
= + 35 ºC
3.5
%
Tj = - 7 ºC
15.9 kW
Tj
= - 7 ºC
2.8
%
Tj = + 30 ºC
14.7 kW
Tj = + 30 ºC
5.6
%
Tj = + 2 ºC
9.7 kW
Tj = + 2 ºC
4.1 %
Tj = + 25 ºC
9.5 kW
Tj
= + 25 ºC
10.3 %
Tj = + 7 ºC
6.3 kW
Tj
= + 7 ºC
7.4 %
Tj = + 20 ºC
6.9 kW
Tj
= + 20 ºC
19.1
%
Tj = + 12 ºC
6.0 kW
Tj
= + 12 ºC
9.6
%
Degradation co- efficient for air
conditioners**
Cdc 0.25 -
T
biv = bivalent temperature
18.0 kW
Tbiv = bivalent temperature
2.6
%
TOL = operation limit
12.3 kW
TOL = operation limit
2.1
%
For air-to-water heat pumps:
Tj = - 15 ºC (if TOL < - 20 ºC)
- kW
For water-to-air heat pumps:
T
j
= - 15 ºC (if TOL < -20 ºC)
- %
Bivalent temperature Tbiv -10 ºC
For water-to-air heat pumps:
Operation limit temperature
TOL -20 ℃
Degradation co- efficient heat
Cdh 0.25 -
OFF
0.020 kW Crankcase heater mode P
CK
OFF
0.020 kW back-up heating capacity * elbu 0.0 kW
Thermostat-off mode PTO
0.020 kW Standby mode PSB 0.020 kW Thermostat-off mode PTO 0.020 kW
Crankcase heater mode P
CK 0.010 kW Standby mode PSB 0.020 kW
Capacity control variable
For air-to-air air conditioner: air
flow rate, outdoor
9840 m³/h Capacity control variable
For air-to-air heat pumps:
air flow rate,outdoor
9840 m³/h
Sound power level,
outdoor
L
WA 77.0 dB
Sound power level,
outdoor
LWA
79.0 dB
For water-/brine-to-air heat
pumps: Rated brine or water
flow rate, outdoor side heat
exchanger
- m³/h
if engine driven: Emissions of
nitrogen oxides
NO
x*** -
mg/kWh
fuel input
GCV
Emissions of nitrogen oxides (if
applicable)
NOx*** -
mg/kWh
fuel input
GCV
GWP of the refrigerant 675
kg CO
2 eq
(100 years)
GWP of the
refrigerant
675
kg CO
2
eq
(100 years)
Contact details Contact details
if applicable: driver of compressor: [electric motor or fuel driven,
gaseous or liquid fuel, internal or external combustion engine]
electric motor
if applicable: driver of compressor: [electric motor or fuel driven,
gaseous or liquid fuel, internal or external combustion engine]
electric motor
Declared coefficient of performance or gas utilization efficiency /
auxiliary energy factor for part load at given outdoor temperatures
Tj
Power consumption in modes other than 'active mode' Power consumption in modes other than 'active mode' Supplementary heater
Parameters shall be declared for the average heating season, parameters for the
warmer and colder heating seasons are optional.
Declared cooling capacity for part load at given outdoor
temperatures Tj and indoor 27º/19ºC (dry/wet bulb)
Declared energy efficiency ratio or gas utilization efficiency /
auxiliary energy factor for part load at given outdoor temperatures
Tj
Declared heating capacity for part load at indoor temperature 20
°C and outdoor temperature Tj
Type of energy input
Pdc
EER
d or
GUEc,bin /
AEF
c,bin
Pdh
COP
d
or
GUEh,bin /
AEF
h,bin
Other items Other items
60.0 dB
Panasonic Testing Centre, Panasonic Marketing Europe GmbH Winsbergring 15, 22525 Hamburg,
Germany
Panasonic Testing Centre, Panasonic Marketing Europe GmbH Winsbergring 15, 22525 Hamburg,
Germany
** If C
dc
is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25.
*** from 26 September 2018.
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on the basis of the
performance of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.
**** Refer to Information requirements for UnitList
** If C
dh is not determined by measurement then the default degradation coefficient of heat pumps shall be 0,25.
*** from 26 September 2018.
Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the
performance of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.
**** Refer to Information requirements for UnitList
Sound power level,
indoor
L
WA 60.0 dB
Sound power level,
indoor
LWA
SM830281-00_欧州向け R32シングル TD&SM.indb 3 20/01/09 15:00:40