4.1 List of Conversion Instructions to FP7
4-3
High-level instructions
FP2/FP2SH instruction
FP7 instruction
High-level
instruction
(Boolean)
Operand condition
Boolean
Name
Operation
unit
Data transfer instructions
F0(MV)
When specifying SV/EV for the
transferring destination of 16-bit
device
EXT
Sign extension
US
When specifying IX for the trasferring
destination of 16-bit device
EXT
Sign extension
SS
When specifying a 16-bit device for
the transferring destination of
SV/EV/IX device
(WX/WY/WR/WL/DT/LD)
BKMV16
Block move (32-bit data
to 16-bit data)
-
F10(BKMV)
When specifying SV/EV for the
transferring destination of 16-bit
device
BKEXT
Block sign extension
US
When specifying IX for the trasferring
destination of 16-bit device
BKEXT
Block sign extension
SS
When specifying a 16-bit device for
the transferring destination of
SV/EV/IX device
(WX/WY/WR/WL/DT/LD)
BKMV16
Block move (32-bit data
to 16-bit data)
-
F7(MV2)
When specifying a 16-bit device only
(WX/WY/WR/WL/DT/LD)
MV2
2 data move
SS
When specifying SV/EV/IX device for
operand
Cannot be converted.
F8(DMV2)
When specifying a 16-bit device only
(WX/WY/WR/WL/DT/LD)
MV2
2 data move
SL
When specifying SV/EV/IX device for
operand
Cannot be converted.
F190(MV3)
When specifying a 16-bit device only
(WX/WY/WR/WL/DT/LD)
MV3
3 data move
SS
When specifying SV/EV/IX device for
operand
Cannot be converted.
F191(DMV3)
When specifying a 16-bit device only
(WX/WY/WR/WL/DT/LD)
MV3
3 data move
SL
When specifying SV/EV/IX device for
operand
Cannot be converted.
Operation instructions
F32(%)
No operand condition
DIVFP2
Division
SS
F33(D%)
No operand condition
DIVFP2
Division
SL
F34(*W)
When specifying a 16-bit device only
(WX/WY/WR/WL/DT/LD)
MLCLIP
Saturated multiplication
SS
When specifying SV/EV/IX device for
operand
Cannot be converted.
F39(D*D)
When specifying a 16-bit device only
(WX/WY/WR/WL/DT/LD)
MLCLIP
Saturated multiplication
SL
When specifying SV/EV/IX device for
operand
Cannot be converted.

Other manuals for Panasonic FP7 Series