EasyManua.ls Logo

Panasonic FPS Series

Panasonic FPS Series
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
High-Speed Counter and Pulse Output
FPΣ User's Manual
130
completed.
Without near home input:
f
t
0Hz
With near home input:
f
t

0Hz
f
t

0Hz
Home input TRUE after deceleration. Home input TRUE during deceleration.
1
Initial and final speed
3
Near home input: TRUE
2
Target speed
4
Home input: TRUE
5
Home input is effective at any time.
Type 2: The home input is effective only after deceleration (started by near home
input) has been completed.
f
t

0Hz
1
Initial and final speed
3
Near home input: TRUE
2
Target speed
4
Home input: TRUE
5
Home input is effective only after deceleration
REFERENCE
Please refer to the FPWIN Pro online help for details and a programming
example.