The correspondence readings between temperature measured by fixing thermistor and HEX readings
Temperature(°C) HEX reading Temperature(°C) HEX reading Temperature(°C) HEX reading
0 E4 84 B8 168 58
1 E4 85 B7 169 57
2 E4 86 B6 170 56
3 E4 87 B5 171 56
4 E4 88 B4 172 55
5 E4 89 B3 173 54
6 E3 90 B2 174 53
7 E3 91 B1 175 52
8 E3 92 B0 176 51
9 E3 93 AE 177 50
10 E3 94 AD 178 4F
11 E2 95 AC 179 4E
12 E2 96 AB 180 4D
13 E2 97 AA 181 4C
14 E2 98 A9 182 4C
15 E1 99 A8 183 4B
16 E1 100 A7 184 4A
17 E1 101 A6 185 4A
18 E1 102 A5 186 49
19 E0 103 A3 187 48
20 E0 104 A2 188 47
21 E0 105 A1 189 46
22 E0 106 A0 190 45
23 DF 107 9E 191 44
24 DF 108 9D 192 44
25 DF 109 9C 193 43
26 DE 110 9C 194 42
27 DE 111 9A 195 41
28 DE 112 99 196 40
29 DD 113 98 197 40
30 DE 114 96 198 3F
31 DD 115 95 199 3E
32 DD 116 94 200 3D
33 DD 117 93 201 3C
34 DC 118 91 202 3C
35 DC 119 90 203 3B
36 DB 120 8F 204 3A
37 DB 121 8D 205 3A
38 DB 122 8D 206 39
39 DA 123 8B 207 38
40 DA 124 8A 208 37
41 D9 125 89 209 37
42 D9 126 88 210 36