EasyManua.ls Logo

Panasonic KX-TCD300FXS

Panasonic KX-TCD300FXS
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13.3. Adjustment Standard (Base Unit)
When connecting the Simulator Equipments for checking, please refer to below.
PbF
BUZ
CLK
VDD2
TP16
TP15
A_1
VDD3
A_2
ANT
VDD1
J101
TP19
TP20
RED
BLACK
J102
J103
J104
LINE_DC
L2T
L1T
CN1
L2R
L1R
DCP
DCM
BELL
Simulator
Loop
Simulator
AF Volt
Meter
AF
OSC
DCPGND
DC POWER
6V
PC
Digital
Volt Meter
(A) (B) (C) (D) (E)
ANTGND
GND
CLK
DECT Tester
CMD60
Frequency
Counter
CHARGE-
CHARGE+
TP16
TP15
Call-ID
Simulator
DTMF
Tester
L1T
TX
J102
RX
J103
GND
J104
GND
VDD1VDD3
VDD2
GND
GND
BUZ
LINE_DC
L1R
Digital
Volt Meter
Digital
Volt Meter
AF
OSC
AF Volt
Meter
Dummy Handset
SP
MIC
OSC
OSC
AF
Volt Meter
600
12
2W
150
6.3V 47uF
+
-
(R)
(F)
(I) (J) (K) (L)
(M) (N) (O) (P)
(H)
(G) (Q)
Note:
(A)-(R) is referred to Check Point (Base Unit) (P.52)
KX-TCD300FXS / KX-TCD300FXT / KX-TCA130FXS / KX-TCA130FXT
57