16 RF SPECIFICATION
16.1. Base Unit
Item Value Refer to -. * Remarks
TX Power 20 dBm ~ 25 dBm Check Point (Base Unit) (I)
Modulation -350 ~ -400/+320 ~ +370 kHz/div Check Point (Base Unit) (J) Data type: Fig31
Frequency Offset -45 kHz ~ +45 kHz Check Point (Base Unit) (K)
Frequency Drift < ± 30 kHz / ms Check Point (Base Unit) (L)
RX Sensitivity < 1000 ppm Check Point (Base Unit) (M)
Timing Accuracy < ± 2.0 ppm Check Point (Base Unit) (N)
RSSI Level 0x22 hex ± A hex Check Point (Base Unit) (O)
Power RAMP Power RAMP is matching Check Point (Base Unit) (P)
*: Refer to Check Point (Base Unit) (P.52)
16.2. Handset
Item Value Refer to -. ** Remarks
TX Power 20 dBm ~ 25 dBm Check Point (Handset) (J)
Modulation -350 ~ -400/+320 ~ +370 kHz/div Check Point (Handset) (K) Data type: Fig31
Frequency Offset -45 kHz ~ +45 kHz Check Point (Handset) (L)
Frequency Drift < ± 30 kHz / ms Check Point (Handset) (M)
RX Sensitivity < 1000 ppm Check Point (Handset) (N)
Timing Accuracy < ± 2.0 ppm Check Point (Handset) (O)
RSSI Level 0x1B hex ± 8 hex (at -81dBm)
0x23 hex ± 8 hex (at -63dBm)
Check Point (Handset) (P)
Power RAMP Power RAMP is matching Check Point (Handset) (Q)
**: Refer to Check Point (Handset) (P.59)