4.1 Troubleshooting
Installation Manual 183
391 Data Link
established
• Connection with PC Phone/
PC Console or Voice
Processing System (DPT
Integration) established or
restored
• This information is logged when
connection with PC Phone/PC
Console or Voice Processing System
(DPT Integration) is established, and
does not indicate an error condition
that needs to be solved.
However, if this is logged frequently
(with "305 Data Link failure"), check the
connection as it may not be done
properly.
392 Clock master card
selected
• Clock master card has been
changed to the one indicated
by the sub code
• Check if the proper card is selected as
the new clock master card
393 LAN Carrier
detected
• IP-GW card connected to the
LAN
• This information is logged when
synchronization of LAN is established
394 IP-GW Core Data
Link established
• IP-GW Core Data Link
established
• This information is logged when IP-GW
Core Data Link is recovered
395 IP-GW
Gatekeeper Error
Cleared
• Connection to the
Gatekeeper is recovered
• This information is logged when
connection to the Gatekeeper is
recovered
396 IP-GW Run • IP-GW is started from a
remote maintenance PC
• This information is logged when IP-GW
is started from a remote maintenance
PC
510* SMDR disconnect • RS-232C cable not
connected
• Breaking of RS-232C cable
• Printer (terminal equipment)
malfunction
• Check the RS-232C cable
• Check the terminal equipment
Error Code Error Message PROBABLE CAUSE SOLUTION