EasyManua.ls Logo

Panasonic KX-TDA100 KX-TDA200 - Page 183

Panasonic KX-TDA100 KX-TDA200
194 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.1 Troubleshooting
Installation Manual 183
391 Data Link
established
Connection with PC Phone/
PC Console or Voice
Processing System (DPT
Integration) established or
restored
This information is logged when
connection with PC Phone/PC
Console or Voice Processing System
(DPT Integration) is established, and
does not indicate an error condition
that needs to be solved.
However, if this is logged frequently
(with "305 Data Link failure"), check the
connection as it may not be done
properly.
392 Clock master card
selected
Clock master card has been
changed to the one indicated
by the sub code
Check if the proper card is selected as
the new clock master card
393 LAN Carrier
detected
IP-GW card connected to the
LAN
This information is logged when
synchronization of LAN is established
394 IP-GW Core Data
Link established
IP-GW Core Data Link
established
This information is logged when IP-GW
Core Data Link is recovered
395 IP-GW
Gatekeeper Error
Cleared
Connection to the
Gatekeeper is recovered
This information is logged when
connection to the Gatekeeper is
recovered
396 IP-GW Run IP-GW is started from a
remote maintenance PC
This information is logged when IP-GW
is started from a remote maintenance
PC
510* SMDR disconnect RS-232C cable not
connected
Breaking of RS-232C cable
Printer (terminal equipment)
malfunction
Check the RS-232C cable
Check the terminal equipment
Error Code Error Message PROBABLE CAUSE SOLUTION

Table of Contents

Related product manuals