11 Measurements and Adjustments
11.1. The Setting Method of JIG (Base Unit)
11.1.1. Preparation
11.1.1.1. Equipment Required
DECT tester: Rohde & Schwarz, CMD 60 is recommended.
Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm).
Hewlett Packard, 53131A is recommended.
Digital multi-meter (DMM): it must be able to measure voltage and current.
Oscilloscope
11.1.1.2. JIG and PC
Serial JIG
JIG Cable: PQZZ1CD300E*
PC which runs in DOS mode
Batch file CD-ROM for setting: PNZZTG8421E
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of resis-
tance. Then you can use it as a JIG Cable for both TCD300
and TCD500 series. (It is an upper compatible JIG Cable.)
11.1.2. PC Setting
11.1.2.1. Connections
Connect the AC adaptor to DC-JACK (base unit).
Connect the JIG Cable GND (black) to GND.
Connect the JIG Cable RX (red) to URX and TX (yellow) to UTX.
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor Old value (k) New value (k)
R2 22 3.3
R3 22 3.3
R4 22 4.7
R7 4.7 10