Value Range 0–3
– 0: Enable "Basic Network Settings
" and "Time Adjust Settings"
– 1: Disable "Basic Network Settings
"
– 2: Disable "Time Adjust Settings"
– 3: Disable "Basic Network Settings" and "Time Adjust Settings"
Default Value 0
5.4.9 LLDP-MED Settings
LLDP_ENABLE
Value Format Integer
Description Selects whether to enable or disable sending and receiving LLDP
frames.
Note
• This setting is available only when "NW_SETTING_ENABLE" is
set to "N".
• You should specify "Y" for only one of "LLDP_ENABLE",
"VLAN_ENABLE", or "IEEE8021X_ENABLE".
If "Y" is specified for two or more of the parameters above, the
settings are prioritized as follows: IEEE8021X_ENABLE >
VLAN_ENABLE > LLDP_ENABLE. Therefore, if "Y" is specified
for both "VLAN_ENABLE" and "LLDP_ENABLE", the
VLAN-related settings are used.
Value Range
• Y: Enable
• N: Disable
Default Value
Y
LLDP_INTERVAL
Value Format Integer
Description Specifies the interval, in seconds, between sending each LLDP frame.
Value Range 1–3600
Default Value 30
LLDP_VLAN_ID_PC
Value Format Integer
Description Specifies the VLAN ID for the PC port when LLDP is on.
Value Range 0–4094
Default Value 0