No.SX-DSV03335
Cate
Pr.
Parameter
Defaul
Cate
Pr.
Parameter
Defaul
Cate
Pr.
Parameter
Defaul
Cate
Pr.
Parameter
Defaul
Cate
Pr.
Parameter
Defaul
6
0 No use
-6
31
Real time auto tuning estimation
s
eed
1 6
62 1st resonance attenuation ratio
0 6
93 No use
-
1 No use
-
32
Real time auto tuning custom
setu
0
63
*
1st anti-resonance frequency
0
94 No use
-
2
Velocity deviation excess setup
0
33 No use
-
64
1st anti-resonance attenuation ratio
0
95
Overload warning detection level
0
3 No use
-
34
*
For Manufacturer use
0
65
*
1st response frequency
0
96
Overload warning release level
0
4 No use
-
35
*
For Manufacturer use
0.10
66
*
2nd resonance frequency
0
97 Function expansion setup 3
0
5
*
Position 3rd gain valid time
0
36
Dynamic brake operation input
setu
0
67
2nd resonance attenuation ratio
0
98 Function expansion setup 4
0
6 Position 3rd gain scale factor
100
37
*
Oscillation detecting level
0
68
*
2nd anti-resonance frequency
0
7
Torque command additional value
0
38 Warning mask setup
4
69
2nd anti-resonance attenuation
ratio
0
8
Positive direction torque
com
ensation value
0
39 Warning mask setup2
0
70
*
2nd response frequency
0
9
Negative direction torque
com
ensation value
0
40 No use
-
71 3rd damping depth
0
10 Function expansion setup
528
41 1st damping depth
0
72 4th damping depth
0
11 For Manufacturer use
100
42
*
Two-stage torque filter time
constant
0
73
*
Load estimation filter
0
12 No use
-
43
Two-stage torque filter attenuation
term
1000
74
*
Torque compensation frequency 1
0
13 No use
-
44 No use
-
75
*
Torque compensation frequency 2
0
14 Emergency stop time at alarm
200
45 No use
-
76 Load estimation count
0
15 2nd over-speed level setup
0
46 No use
-
77 No use
-
16 No use
-
47 Function expansion settings 2
1
78 No use
-
17 No use
-
48
*
Adjust filter
Size A 1.1
Size B-C 1.2
Size D-H 1.
79 No use
-
18
*
Power-up wait time
0
49
Command / tuning filter damping
15
80 No use
-
19 For Manufacturer use
0
50
*
Viscous friction compensation
ain
0
81 No use
-
20 For Manufacturer use
0
51
Immediate cessation completion
wait time
0
82 No use
-
21 For Manufacturer use
0
52 For Manufacturer use
0
83 No use
-
22
A,B phase feedback scale pulse
out
ut selection
0
53 For Manufacturer use
0
84 No use
-
23
Load change compensation gain
0
54 For Manufacturer use
0
85
Retracting operation condition
settin
0
24
*
Load change compensation filter
0.53
55 No use
-
86
Retracting operation alarm setting
0
25 No use
-
56 No use
-
87 For Manufacturer use
0
26 No use
-
57
Torque saturation anomaly
detection time
0
88 For Manufacturer use
0
27
Warning latch state setup
3
58 For Manufacturer use
0
89 No use
-
28 No use
-
59 For Manufacturer use
0
90 No use
-
29 No use
-
60 2nd damping depth
0
91 No use
-
30 For Manufacturer use
0
61
*
1st resonance frequency
0.0
92 No use
-
MODEL MINAS-A6B(BL/BM) series
7/11
*1 When checking directly value of parameter-file with a text data etc., it does not show the decimal point. Ex) Pr6.24 Load change compensation filter ・・・ Value of Panaterm : 0.53 / Value of parameter-file : 53
* Parameter names in the table correspond to the DD motor (rotary type). For parameter names and setting values corresponding to linear motors, refer to the technical document.
PARAMETER