EasyManua.ls Logo

Panasonic PT-CW230E

Panasonic PT-CW230E
79 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
68
- ENGLISH
Appendix
J
Status Read Command
Format
The projector control command is dened as one command line that starts with "CR" and ends with carriage
return.
PC
Projector
Projector
PC
Command
Processing
“C “R”
“0”
CR
ACK
CR
(A few ms ~ 5s)
Command Function Projector
Return
Projector status
CR0
Status Read
00 Power On
80 Stand-by mode
40 Countdown
20 Cooling down
10 Power Malfunction
28 Cooling down at the temperature anomaly
24 Cooling down at Power Management mode
04 Power Management mode after Cooling down
21 Cooling down after the projector is turned off when the lamps are out.
81 Stand-by mode after Cooling down when the lamp is out.
CR6 Temperature Read
%1 %2
%3
%1 = Temperature at Sensor 1 (˚C)
%2 = Temperature at Sensor 2 (˚C)
%3 = Temperature at Sensor 3 (˚C)
(ex.) %1 = 12.3˚C, %2 = 23.4˚C, %3 = 34.5˚C
--> The projector displays “12.3 23.4 34.5”
( For each sensor, two digit and the tenth place numbers are displayed
with a space between each temperature.)
? Communication failure