INF-31
SECTION 1 SERVICE INFORMATION
Bit Error code (hex) Factor Description
64
UPPER
00000000 00000001 Not used
65 00000000 00000002 Not used
66 00000000 00000004 Mechanical shutter error Mechanical shutter operation error
67 00000000 00000008 Iris error Iris operation error
68 00000000 00000010 Not used
69 00000000 00000020 Not used
70 00000000 00000040 Not used
71 00000000 00000080 Not used
72 00000000 00000100 Lamp not initialized Lamp memory is not initialized
73 00000000 00000200 Not used
74 00000000 00000400 Not used
75 00000000 00000800 Not used
76 00000000 00001000 Not used
77 00000000 00002000 Not used
78 00000000 00004000 Not used
79 00000000 00008000 Not used
80 00000000 00010000 FPGAconfigurationerror Signal processing part error
81 00000000 00020000 Not used
82 00000000 00040000 Not used
83 00000000 00080000 Not used
84 00000000 00100000 Not used
85 00000000 00200000 Not used
86 00000000 00400000 Lens mounter operation error
• Motor operation error
• Position detection sensor error
87 00000000 00800000 Ballast communication error Communication error on ballast unit
88 00000000 01000000 Not used
89 00000000 02000000 Not used
90 00000000 04000000 Not used
91 00000000 08000000 Light output limit Intake air temperature is higher than 40ºC
92 00000000 10000000 Not used
93 00000000 20000000 Not used
94 00000000 40000000 Not used
95 00000000 80000000 Installation angle warning Projector tilted more than ± 15º
96 00000001 00000000 Not used
97 00000002 00000000 Not used
98 00000004 00000000 Sub microprocessor communication error Communication error on sub-microprocessor
99 00000008 00000000 IICcommunicationerror1(RTC) Device operation failure on signal processing part
100 00000010 00000000 IICcommunicationerror2(EEPROM)
101 00000020 00000000 IICcommunicationerror3(LAMP1EEPROM)
102 00000040 00000000 Not used
103 00000080 00000000 Not used
104 00000100 00000000 Not used
105 00000200 00000000 IICcommunicationerror7(EDIDDIGITAL)
106 00000400 00000000 IICcommunicationerror8(EDIDANALOG)
107 00000800 00000000 IIC communication error 9(ADC1)
108 00001000 00000000 IIC communication error 10(ADC2)
109 00002000 00000000 IIC communication error 11(Angle sensor)
110 00004000 00000000 IIC communication error 12(Pressure sensor) Disconnectingconnector/cable
111 00008000 00000000 IIC communication error13(HDBaseT) Device failure
112 00010000 00000000 IIC communication error14(DisplayPort)
113 00020000 00000000 IICcommunicationerror15(ANALOGSW)
114 00040000 00000000 IIC communication error 16(AUdio amp.)
115 00080000 00000000 A-P.C. board not initialized EEPROMnotinitialized
116 00100000 00000000 Not used
117 00200000 00000000 Not used
118 00400000 00000000 Not used
119 00800000 00000000 Not used
120 01000000 00000000 Not used
121 02000000 00000000 Not used
122 04000000 00000000 Not used
123 08000000 00000000 Not used
124 10000000 00000000 Not used
125 20000000 00000000 Not used
126 40000000 00000000 Not used
127 80000000 00000000 Internal error (Used for main microprocessor) Error "Axx" occurs