ADJ-9
SECTION 3 ADJUSTMENTS
1. 5. 4. Restore the data (after board replacing)
1.Settheprojectorto"Normal-Standby"mode(POWERindicatorisLightinginred).
2. Start up the software "ServiceEZ770.exe" with a PC.
3.Selectlanguageandclickthe[OK]button.
4. 1) Choose the available serial port number on your PC.
2) Choose a model number.
3) Click the [Data] button.
5.1)Clickthe[Transmission]buttonofGammaData.
2) Select the save place and click the [ Open(O) ] button.
3) When the progress bar reaches the right-side end, the transmission of data is completion.
4)RestoretheUniformitycorrectiondatainthesameprocedureof1-3.
6. After completing the writing, turn the main power off and on, and check the color uniformity and gamma characteristic of
the projector.
k
j
l
j
k