EasyManua.ls Logo

Panasonic PT-F100NTU - LCD Panel Discrimination; LCD Panel Combination; Replacement of Incidence Polarizer (G)

Panasonic PT-F100NTU
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
shifted by your fingers.
Note:
·
The panel adjustment fittings set (panel attachment,
panel adjuster and base plate) is an option for
service.
6. Reassemble the projector in the reverse order of
disassembling, but leave the upper case and the screws
fixing the A-P.C.Board block as they are removed.
7. Adjust the convergence according to the section 8.4.
"Convergence Adjustment".
8. After the adjustment, while paying attention not to vary the
adjusting result, tighten the 2 screws fixing the panel
attachment with a hexagon head wrench.
Notes:
·
Prepare a hexagon head wrench processed short.
9. Reassemble the projector as it was.
7.20. LCD Panel Discrimination
ID-tag seal color LCD panel
Red LCD panel (R)
Blue LCD panel (B)
(No seal) LCD panel (G)
·
Since the ID-tag seal is pasted to the FPC of LCD Panel,
(R), (G) or (B) can be easily identified by the color of the
seal.
·
Finally, identify the panel color by the part number printed
on the FPC.
7.21. LCD Panel Combination
·
Part number is printed on the FPC of LCD Panel.
·
When replacing LCD Panel, use a component which has
the same part number as the original.
LCD
panel
Combination1 Combination2
R L5BDAYY00068
(L3P07X-65G01)
L5BDAYY00071
(L3P07X-66G01)
G L5BDAYY00072
(L3P07X-66G01)
L5BDAYY00069
(L3P07X-65G01)
B L5BDAYY00070
(L3P07X-65G01)
L5BDAYY00073
(L3P07X-66G01)
7.22. Replacement of Incidence
Polarizer (G)
1. Remove the A-P.C.Board block according to the steps 1
through 4 in the section 7.3. "Removal of A-P.C.Board".
2. Mark positions of the incidence polarizer (G).
Note:
·
Mark accurately as possible because the marks will
be used for resetting the incidence polarizer
position.
3. Unscrew the 1 screw and remove the incidence polarizer
(G).
4. Attach a new incidence polarizer (G) and align it with the
mark.
5. Tighten the 1 screw with care not to move the incidence
polarizer position.
19
PT-F100NTU / PT-F100NTE / PT-F100NTEA / PT-F100U / PT-F100E / PT-F100EA

Table of Contents

Other manuals for Panasonic PT-F100NTU