2.40. CLOSED CAPTION SETTING
Hexadecimal 02h 4Fh 43h 43h 3Ah *1 03h
Characte
r
O C C : *2
Parameters (*1,*2)
OFF CC1 CC2 CC3 CC4
Hexadecimal 30h 31h 32h 33h 34h
Characte
r
0 1 2 3 4
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 43h 43h 3Ah *1 03h
Characte
r
O C C : *2
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
× × × ×
Note:
- This command is effective only when the system is fixed with “NTSC” and the proper signals (NTSC Video or S-Video
signal) are input.
2.41. SCREEN ASPECT
Hexadecimal 02h 56h 53h 46h 3Ah *1 03h
Characte
r
V SF :*2
Parameters (*1,*2)
16:10 16:9 4:3
Hexadecimal 30h 31h 32h
Characte
r
01 2
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 56h 53h 46h 3Ah *1 03h
Characte
r
V S F : *2
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
× × ×
2.42. LOGO
Hexadecimal 02h 4Dh 4Ch 4Fh 3Ah *1 03h
Characte
r
M L O : *2
Parameters (*1,*2)
OFF USER DEFAULT
Hexadecimal 30h 31h 32h
Characte
r
0 1 2
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Dh 4Ch 4Fh 3Ah *1 03h
Characte
r
M L O : *2
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
× × ×
Note:
- When the Logo PIN code is “ON”, ER401 is returned.
- When the user registered Logo is not available, “OFF” and “DEFAULT” are effectice. In other cases, ER401 is returned.