29/33
2.81. Query INPUT SEARCH
Hexadecimal 02h 51h 53h 52h 03h
Characte
Q S R
■Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 03h
Characte
*2
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
○ ○ × ○ ○ ○
■Parameters (*1,*2)
OFF ON
Hexadecimal 30h 31h
Characte
01
2.82. Query BACKGROUND
Hexadecimal 02h 51h 42h 43h 03h
Characte
Q B C
■Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 03h
Characte
*2
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
○ ○ × ○ ○ ○
■Parameters (*1,*2)
BLUE BLACK USER
Hexadecimal 30h 31h 32h
Characte
0 1 2
2.83. Query DIRECT ON
Hexadecimal 02h 51h 50h 59h 03h
Characte
Q P Y
■Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h *1 03h
Characte
*2
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
○ ○ × ○ ○ ○
■Parameters (*1,*2)
2.84. Query INSTALLATION
Hexadecimal 02h 51h 53h 50h 03h
Characte
Q S P
■Response (Callback)
Hexadecimal 02h *1 03h
Characte
*2
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
○ ○ × ○ ○ ○
■Parameters (*1,*2)
FRONT/DESK REAR/DESK FRONT / CEILING REAR/CEILING
Hexadecimal 30h 31h 32h 33h
Characte
0 1 2 3
OFF ON
Hexadecimal 30h 31h
Characte
0 1