2. BASIC CONTROL COMMAND
Explanatory notes
: Enable
×: Disable
2.1. Power ON (LAMP ON)
Hexadecimal 02h 50h 4Fh 4Eh 03h
Characte
r
P O N
Response (Callback)
In the period when the command can be accepted (This command in power-on condition is included.)
Hexadecimal 02h 50h 4Fh 4Eh 03h
Characte
r
P O N
Acceptability
SECURITY STANDBY
(NETWORK)
STAMDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
× ×××
Note:
- When you confirm whether to have succeeded in power-on, confirm it by QPW (Query Power) command after
receiving the callback of PON command.
2.2. Power OFF (STANDBY)
Hexadecimal 02h 50h 4Fh 46h 03h
Characte
r
P O F
Response (Callback)
In the period when the command can be accepted (This command in power-on condition is included.)
Hexadecimal 02h 50h 4Fh 46h 03h
Characte
r
P O F
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
××
Note:
- When you confirm whether to have succeeded in power-off, confirm it by QPW (Query Power) command after
receiving the callback of PON command.
2.3. VOLUME () Key
Hexadecimal 02h 41h 55h 55h 03h
Characte
r
A U U
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 41h 55h 55h 03h
Characte
r
A U U
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
× × ×
2.4. VOLUME () Key
Hexadecimal 02h 41h 55h 44h 03h
Characte
r
A U D
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 41h 55h 44h 03h
Characte
r
A U D
Acceptability
SECURITY STANDBY
(NETWORK)
STANDBY
(ECO)
NO SIGNAL AV MUTE FREEZE
× × ×