Maintenance/replacement
Before performing maintenance/replacement
f Make sure to turn off the power before maintaining the projector or replacing the unit. (x page 38)
f When switching off the projector, make sure to follow the procedures in “Powering Off the Projector”. (x page 38)
Maintenance
Outer case
Wipe off dirt and dust with a soft, dry cloth.
f If the dirt is persistent, soak the cloth with water and wring it thoroughly before wiping. Dry off the projector with a dry cloth.
f Do not use benzene, thinner, or rubbing alcohol, other solvents, or household cleaners. Doing so may deteriorate the outer
case.
f When using chemically treated dust cloths, follow the instructions written on its packaging.
Lens front surface
Wipe off dirt and dust from the front surface of the lens with a soft clean cloth.
f Do not use a cloth that is uffy, dusty, or soaked with oil/water.
f Since the lens is fragile, do not use excessive force when wiping the lens.
Attention
f The lens is made of glass. Impacts or excessive force when wiping may scratch its surface. Handle with care.
Replacing the unit
Air lter unit
The estimated duration before replacement is about 7 000 hours, but it is recommended to replace the air lter unit early if the
projector is used in dusty environment.
Replace the air lter unit in the following cases:
f If the air lter unit is clogged, a “Temperature Warning” message is displayed on the screen, and then the temperature
indicator <TEMP> lights red, the power of the projector may be turned off automatically and entered into standby mode.
f “FILTER COUNTER has reached the set time.” is displayed.
When purchasing the optional air lter unit (Model No.: ET-RFV400), consult your dealer.
How to replace the air lter unit
Attention
f Make sure to turn off the power before replacing the air lter unit.
f Make sure that the projector is stable, and perform the replacement in a safe place where the unit will not be damaged even
if you drop the air lter unit.
f After replacing the air lter, reset the lter counter. Otherwise, “FILTER COUNTER has reached the set time.” will appear on
screen.
1) Remove the air filter cover.
f Pull out the air lter cover from the hook of the projector while slightly pushing upward the tabs of the air lter cover and
open it in the direction of the arrow in gure.
Tabs
Air lter cover
2) Remove the air filter unit.
f Hold the tab on the left side of the air lter unit and pull out in the direction of the arrow.
f After removing the air lter unit, remove foreign objects and dust from the air lter compartment and the projector’s air
intake port if there are any.
Tab
Air lter unit