7 Troubleshooting Guide
7.1. Self Check
7.1.1. Display Indication
1. Self-check is used to automatically check the bus line
controlled circuit of the Plasma display.
2. There are 2 kinds of Self-check mode
Self-check indication and forced to factory shipment
setting :
Press the down button on the customer controls at the
bottom of the set, at the same time pressing the OFF-
TIMER button on the remote control, and the screen will
show.
Self-check indication only:
Press [5] button on the remote control at ID mode in CAT
mode.(See chapter 6.1.)
If the IIC ports have been checked and found to be incorrect
Or not located then [ - -] will appear in place of [OK]
[01] in the line of the [PTCT] means the number of blinks of the
Power LED is 1. (Reference to 7.1.2)
[H09] in the line of the [PTCT] is the error code.
To exit the CAT mode switch off the main power.
Note:
The line of the [PTCT] displays when you get into the Self-
check mode for the first time only after the Power LED
blinks.