10.1.3. Initialization Pulse Adjust
1. Set Aging pattern (white pattern signal) by IIC mode.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
3. Connect Oscilloscope to TP801 and adjust VR16601 for 127.5V ± 2.5V.
Test Point Volume Level
TP801 (SU3) VR16601 (SCU) 127.5V ± 2.5V
at 50
µs period on the down slope.