33
TH-58PF12UK
10 Measurements and Adjustments
10.1. Adjustment Procedure
10.1.1. Driver Set-up
10.1.1.1. Item / Preparation
1. Set Aging pattern (white pattern signal) by IIC mode.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
Caution
1. First perform Vsus adjustment.
2. Confirmation of Vscn voltage should be performed after
confirmation of Vad adjustment.
When Vad=-165V, Voltage of Vscn is -20V ±4V.
10.1.1.2. Adjustments
Adjust driver section voltages. (Refer to the panel data on the
Panel Label).
Check or adjust the following voltages with the multimeter.
*See the Panel Label.
Name Test Point Voltage Volume Remarks
Vsus TPVSUS
(SS)
Vsus ± 2V VR251 (P) *
Ve TPVE (SS) Ve ± 2.5V Fixed *
Vset TPVSET
(SC)
290V ± 9V Fixed
Vad TPVAD (SC) -165V ± 2V VR16600
(SC)
Vscn TPVSCN
(SC)
Vad_base:
+145V±4V
GND_base:
-20V±6V
Fixed