31
When the “Reduce flow”
message appears on the
LCD display
Blink
The balance cartridge
life is displayed
(see page 62).
Example:
The LCD displays will be cleared about 30 to 45 seconds after a button has been operated or after
the faucet has been turned off (in order to conserve power). They light up when another button
is operated or the water flows to the Alkaline Ionizer.
When the water flow has dropped (to less than 1.0 liter or so a minute), the balance cartridge life
is displayed even while water is running through the Alkaline Ionizer. In a case like this, the water
is not electrolyzed (no electrolysis and no water treatment).
Note
LCD displays which appear during operation
During use Standby status
“Electrolysis On” is displayed
while the Alkaline Ionizer is
making alkaline ion water or
weak acidic water.
When the
faucet is
turned off ...
Characters and pictographs indicating the application are
displayed alternately.
Example: When the “Alkaline 1” (Drinking water for new user) is
selected
pH fine adjustment setting
displayed here (see page 42)
While “Electrolysis On” is displayed, a display is provided to indicate roughly the electrolytic strength (amount of
power used for the electrolysis). It does not appear while the water is turned off or while purified water is being
produced.
Ʃ The electrolytic strength changes (in 8 steps) depending on the water quality selector buttons and water flow
(amount of water being electrolyzed) used.
Electrolysis signal
To turn off the electrolysis signal
Refer to “How to set” (see page 57), and set “Electrolysis Signal” to “OFF”.
Lighted
Indicates the
electrolytic
strength.
Lights one block
at a time from
bottom to top.
Lights one
block at a time
from the top
and bottom
toward the
center.
During preparations
Electrolysis On
At intervals of approx.
2 seconds
ZGS0TK7585HKE0Z.indb 31ZGS0TK7585HKE0Z.indb 31 2009/12/09 9:50:302009/12/09 9:50:30