Troubleshooting
Before asking for repairs, check the symptoms with the following table.
Contact your dealer if a problem cannot be solved even after checking and trying the solution in the
table or a problem is not described below.
Symptom Cause/solution
Reference
pages
No image displayed
•Arethepowercordandcoaxialcable
connected appropriately?
Check whether the connection is
appropriately established.
30
•Istheadjustingmonitorconnected?
Check whether connection is estab-
lished.
24
•Isthemonitorbrightnessappropriately
adjusted, or is the contrast appropriately
adjusted?
Check whether the monitor settings
are appropriate.
•Weretheshockabsorbersinthedome
cover already removed?
Confirm whether the shock absorbers
have been already removed.
Blurred image
•Isthedomecoverfreefromcontamina-
tion and/or flaws?
Check the dome cover.
•Isthefocusadjustedcorrectly?
Check if the focus is adjusted correct-
ly.
25
•Isthelensofthecamerasoiledwithdirt
or dust?
Check whether the lens of the camera
is clean.
Damaged power cord
sheathing
The power cord and connector is dam-
aged. Use of the damaged cord or con-
nector may cause electric shock or fire.
Turn off the power immediately and request
repair to your dealer.
Heated portion of power line
consisting of power cord
during use
Warmed power cord or loos-
ened connection by bending
or stretching during use