EasyManua.ls Logo

Paradise Datacom 205486 REV F - Table 11-7: System Settings Data Values

Paradise Datacom 205486 REV F
144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operations Manual, HPA2, Compact Outdoor SSPA 208495 REV B 119
Table 11-7: System Settings Data Values
Data
Address
# Bytes Description Limits and Byte Values
1 1 System Operation Mode
Single Amplifier = 255; 1:1 Redundant = 0; Dual 1:1 = 1
(version 3.60); Maintenance Switch =2 (version 5.05)
2 1 System Hierarchical Address HPA 1= 0; HPA 2= 255
3 1 Unit Start Up State (in Redundancy) Standby Amplifier = 0; On Line Amplifier = 1
4 1 Mute State
Mute Clear (Transmit Enable) = 255
Mute Set (Transmit Disable) = 0
5 1
Attenuation Level
(dB down from maximum gain)
[1 bit for every 0.1 dB]
0 dB attenuation = 0; 20 dB attenuation = 200
6 1 Module Gain Control Authority
Serial Port Gain Control = 255
External Analog Voltage Gain Control = 0
7 1 Amplifier Network Address 0 to 255
8 1 High Temperature Alarm Threshold 0 to 125 (in °C)
9 1 SSPA module Calibration Mode
Temperature Compensated = 255 (normal state)
Calibration Mode = 0
10 1 SSPA Spare Fault Status
Ignore Spare Fault = 255
Fault on value of window on ADC channel = 0 to 7
Fault on External Mute = 8
11 1 SSPA Spare Fault Handling
Minor Fault (no effect on Summary Fault) = 255
Major Fault (Triggers Summary Fault) = 0
Major Fault with Mute (Transmit Disabled) = 1
12 1 SSPA Auxiliary Fault Status
Ignore Auxiliary Fault = 255
Fault on Logic Low State = 1
Fault on Logic High State = 0
Startup in Low Z State = 2
Startup in High Z State = 3
(version 3.50 - See SierraCom Protocol for details)
13 1 SSPA Auxiliary Fault Handling
Minor Fault (No effect on Summary) = 255
Major Fault (Triggers Summary Fault) = 0
Major Fault with Mute (Transmit Disabled) =1
Minor Fault with Mute = 2 (version 3.50)
14 1 Block Up Converter Fault Status
Ignore BUC Fault = 255
Fault on Logic Low State = 1
Fault on Logic High State = 0
15 1 Block Up Converter Fault Handling
Minor Fault (no effect on Summary Fault) = 255
Major Fault (Triggers Summary Fault) =0
Major Fault with Mute (Transmit Disabled) = 1
16 1 Protocol Select
Normal Protocol = 255
VSAT Legacy Protocol = 2 (version 3.50; compatible with
SierraCom VSAT BUC and NDSat SkyWAN modem)
IPNet (Ethernet UDP + Web M&C) = 2;
SNMP V1 = 3
17 1 Baud Rate Select 9600 = 255; 38400 = 0; 19200 = 1; 4800 = 2; 2400 = 3
18-19 2 Reserved Reserved for Factory use.
20 1 Standby Mode Hot standby=255; Cold standby=0 (version 3.50)
21 1 BUC Reference Autoswitch = 0; External = 1; Internal = 2 (version 3.60)
(continued)
Note: Data length must be at least two bytes to form integer with the lower byte sent first. If an odd number of bytes is received, the last byte
will be saved as the lower byte of the integer and the upper part will be zero.

Table of Contents