120 208495 REV B Operations Manual, HPA2, Compact Outdoor SSPA
Data
Address
# Bytes Description Limits and Byte Values
22 1 Forward RF Fault Status
Disabled =255;
Fault on low RF threshold = 0
10% Forward RF power window = 1
15% Forward RF power window = 2
Fault on High RF threshold = 3
23 1 Forward RF Fault Handling
Minor Fault (no effect on Summary Fault) = 255
Major Fault (Triggers Summary Fault) = 0
24 1 Forward RF fault threshold
0—80 dBm. Value used as Low, Window centre point or High
threshold, depending on Forward RF Fault status setting.
25—28 4 Reserved locations, Factory use only 1-255
29—32 4 SSPA IP address 1-255, Bytes alignment High to Low
33—36 4 SSPA IP Gateway Address 1-255, Bytes alignment High to Low
37—40 4 SSPA IP Subnet Mask 1-255, Bytes alignment High to Low
41—42 2 SSPA IP port 1-255, Bytes alignment High to Low
43—46 4 SSPA IP Lock address 1-255, Bytes alignment High to Low
Table 11-7: System Settings Data Values (continued)
Data
Address
# Bytes Description Limits and valid values
1 2
Low Current Fault Threshold
(Master Side)
Minimum value = 0
Maximum value = 1023
2 2
Spare Fault Window
Lower Limit
Minimum value = 0
Maximum value = 1023
3 2
Spare Fault Window
Upper Limit
Minimum value = 0
Maximum value = 1023
4 2
Low Current Fault Threshold
(Slave Side)
Minimum value = 0
Maximum value = 1023
5 2
Low Regulator Voltage Thresh-
old (Master Side)
Minimum value = 0
Maximum value = 1023
6 2
Low Regulator Voltage Thresh-
old (Slave Side)
Minimum value = 0
Maximum value = 1023
Table 11-8: System Threshold Data Values