Operations Manual, HPA2, Compact Outdoor SSPA 208495 REV B 137
11.3.1 Connecting to a MIB browser
For a MIB browser application example, we will be using the freeware browser GetIf, version
2.3.1. Other browsers are available for download at http://www.snmplink.org/Tools.html.
1. Copy the provided Teledyne Paradise Datacom LLC MIB file into the Getif Mibs
subfolder.
2. Start the GetIf application.
3. Select the unit IP address and community strings in the relevant text boxes on the
Parameters tab (Figure 11-9, Item 1) and click Start (Figure 11-9, Item 2).
4. Select the MIBBrowser tab (Figure 11-9, Item 3).
5. Click on the ‘iso’ main entity on the MIB tree (Figure 11-10, Item 1), and click Start
(Figure 11-10, Item 2).
6. Update data will be displayed in the output data box (Figure 11-10, Item 3).
Figure 11-9: GetIF Application Parameters Tab
1. Set these
parameters
3. Select the
MBrowser tab
2. Click Start
Figure 11-10: Getif MBrowser window, with update data in output data box
2. Click Start
1. Select ‘iso’
3. Data output