EasyManua.ls Logo

Paradise Datacom 205486 REV F - Figure B-2: Redundant System Using RCP2-1100 Controller

Paradise Datacom 205486 REV F
144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
142 208495 REV B Operations Manual, HPA2, Compact Outdoor SSPA
Alternate Redundant System Configurations
Mixing Compact Outdoor SSPA with other manufacturer Amplifier
Configuring redundant systems with other manufacturers amplifiers can be achieved by using
an external controller such as the Teledyne Paradise Datacom RCP2-1100. The external
controller is required because the internal controller in the Compact Outdoor Amplifier is
specifically designed to operate with other Compact Outdoor SSPAs.
The RCP2-1100 controller will control the 1:1 redundant system provided that the other
manufacturer’s amplifier is equipped with a form A or form C summary alarm relay contact.
Such a configuration is shown in the schematic below. The RCP2-1100 is a 1RU remote
controller capable of driving a waveguide switch that is located several hundred feet from the
controller.
Figure B-2: Redundant System using RCP2-1100 Controller
&
CONTROL
MONITOR
A
B
C
1
2
4
3
RF Output
Transfer Switch
CONTROL CABLE
C N.C.N.O.
RCP2-1100
J8
J3
4
1
2
External Alarm
Cable
RF Input
F
D
Pos 1
Pos 2
U
W
P
S
&
CONTROL
MONITOR
Open on FaultClosed on Fault
SSPA 2
SSPA 1
Closed on Fault
Open on Fault
a
bL
Aternate SSPA
Compact Outdoor SSPA

Table of Contents