20 Reference & Installation Manual
†If 2-wire smoke with ATZ
6.5.2 Ademco Contact ID (Programmable Codes)
Please note that this format must use a 4-digit system account code (see System Account Codes on page 19).
Ademco Contact ID is a fast communicator format that uses tone transmission instead of pulse transmission. Use the
Ademco Contact event list of industry standard messages and event codes found in Table 8 to program the desired
event codes into addresses 300 to 527.
Enter FF to program the default Ademco Contact ID report code when using the Ademco Contact ID
(programmable codes) report format.
Table 8: Programmable Contact ID Event Codes
Timer Loss/Timer Programmed 501 and 509 Time/Date Reset 625
TLM Trouble Restore 511 Telco 1 Fault 351
Test Report 512 Periodic Test 602
Panic #1 (keys 1 and 3) 513 Panic Alarm 120
Panic #2 (keys 4 and 6) 514 Medical 100
Panic #3 (keys 7 and 9) 515 Fire Alarm 110
Duress 520 Duress 121
Late to Close or No Movement 516 and 517 Late to Open/Close 404
Bypassed Zone on Arming N / A Bypass 570
Partial Arming 518 Group Bypass 574
Recent Close 519 Open/Close 400
Espload Log-In 524 Remote Access 410
Program Change 525 Program Changed 306
Closing Delinquency 521 System Inactivity 654
All addresses from 300 to 527 (sections 11 to 67) programmed with values other than [2
ND] [2ND] will report the contact ID codes corresponding to
the values programmed. Values to be programmed should be selected from this table.
CID Reporting Code Prog. Value CID Reporting Code Prog. Value
100: A
UXILIARY ALARM [2ND] / [1] 300: SYSTEM TROUBLE [2] / [2]
110: F
IRE ALARM [2ND] / [2] 301: AC LOSS [2] / [3]
111: F
IRE SMOKE [2ND] / [3] 302: LOW SYSTEM BATTERY [2] / [4]
112: C
OMBUSTION [2ND] / [4] 305: SYSTEM RESET [2] / [5]
113: W
ATER FLOW [2ND] / [5] 306: PROGRAM CHANGED [2] / [6]
114: H
EAT [2ND] / [6] 309: BATTERY TEST FAIL [2] / [7]
115: P
ULLSTATION [2ND] / [7] 320: SOUNDER/RELAY TROUBLE [2] / [8]
116: D
UCT [2ND] / [8] 321: BELL 1 TROUBLE [2] / [9]
117: F
LAME [2ND] / [9] 323: ALARM RELAY TROUBLE [2] / [0]
118: N
EAR ALARM [2ND] / [0] 350: COMMUNICATION TROUBLE [2] / [STAY]
120: P
ANIC ALARM [2ND] / [STAY] 351: TELCO 1 FAULT [2] / [AWAY] OR [FORCE]
121: D
URESS [2ND] / [AWAY] OR [FORCE] 354: FAIL TO COMMUNICATE [2] / [BYP]
122: S
ILENT PANIC [2ND] / [BYP] 370: PROTECTION LOOP TROUBLE [2] / [MEM]
123: A
UDIBLE PANIC [2ND] / [MEM] 371:
P
ROTECTION
L
OOP
O
PEN
[2] / [TRBL]
130: B
URGLARY [2ND] / [TRBL] 372: PROTECTION LOOP SHORT [3] / [2ND]
131: P
ERIMETER BURGLARY [1] / [2ND] 373: FIRE LOOP TROUBLE [3] / [1]
132: I
NTERIOR BURGLARY [1] / [1] 382: SENSOR TROUBLE [3] / [2]
133: 24H
R BURGLARY [1] / [2] 383: SENSOR TAMPER [3] / [3]
136: B
URGLARY OUTDOOR [1] / [3] 400: OPEN / CLOSE [3] / [4]
137: B
URGLARY TAMPER [1] / [4] 401: OPEN / CLOSE BY USER # [3] / [5]
138: B
URGLARY NEAR ALARM [1] / [5] 402: GROUP OPEN / CLOSE [3] / [6]
140: G
ENERAL ALARM [1] / [6] 403: AUTOMATIC OPENING / CLOSING [3] / [7]
150: 24 H
OUR AUXILIARY [1] / [7] 404: LATE TO OPEN / CLOSE [3] / [8]
151: G
AS DETECTED [1] / [8] 407: REMOTE ARM DOWNLOAD [3] / [9]
152: R
EFRIGERATION [1] / [9] 410: REMOTE ACCESS [3] / [0]
153: L
OSS OF HEAT [1] / [0] 441: OPEN / CLOSE - STAY MODE [3] / [STAY]
154: W
ATER LEAKAGE [1] / [STAY] 570: BYPASS [3] / [AWAY] OR [FORCE]
155: F
OIL BREAK ALARM [1] / [AWAY] OR [FORCE] 572: 24 HOUR ZONE BYPASS [3] / [BYP]
156: D
AY TROUBLE ALARM [1] / [BYP] 573: BURGLARY BYPASS # [3] / [MEM]
157: L
OW GAS LEVEL [1] / [MEM] 574: GROUP BYPASS [3] / [TRBL]
158: H
IGH TEMPERATURE [1] / [TRBL] 601: MANUAL TEST [4] / [2ND]
159: L
OW TEMPERATURE [2] / [2ND] 602: PERIODIC TEST [4] / [1]
161: L
OSS AIR FLOW [2] / [1] 625: TIME / DATE RESET [4] / [2]
654: S
YSTEM INACTIVITY [4] / [3]
System Event Event Code Addresses Contact ID Message Contact ID Code #