46 Reference & Installation Manual
authority, or electrician, as appropriate.
The Load Number (LN) assigned to each terminal device denotes the
percentage of the total load to be connected to a telephone loop which is
used by the device, to prevent overloading. The termination on a loop may
consist of any combination of devices subject only to the requirement that
the total of the Load Numbers of all of the devices does not exceed 100.
Industry Canada certification is only applicable to installation of devices
which include transformers approved by the Canadian Standards
Association (CSA).
Requirements and Guidelines for UL Installations
UL has only evaluated the 728ULT for compatibility with the
Ademco model 685, FBI model CP220FB, SUR-GUARD SG-
MLR2-D6 and Silent Knight model 9000.
UL listed in accordance with standard UL1023 (Household Burglar
- Alarm System Units), standard UL985 (Household Fire Warning
Units) and UL1635 (Digital Alarm Communicator System Units).
Look for the UL mark on the product. Only products bearing this
mark are UL listed.
Some operational features are not permitted in UL installations. To
respect the standards for household applications, the installer
should follow these guidelines when configuring the system.
1. All components of the system should be UL listed for the intended
application.
2. If the installation is a FIRE ALARM application, refer to NFPA Standard
74 for details on smoke detector locations. There must be at least one
UL-Listed Indoor Fire Alarm Warning Signalling Appliance.
3. For UL/cUL Burglar Applications:
Maximum entry time = UL 45 seconds/cUL 60 seconds
Maximum exit time = UL 60 seconds/cUL 120 seconds
Minimum bell cutoff time = 5 minutes
4. Keypad Models 639, 642 and 646 are not UL/cUL listed. Do not use the
708 or Esprint with a UL installation--they are not UL listed.
5. The upload/download software should not be used on UL listed systems.
6. All outputs are Class 2 or power-limited, except for the battery terminal.
The Class 2 and power-limited fire alarm circuits shall be installed using
CL3, CL3R, CL3P or substitute cable permitted by the National Electrical
Code, ANSI/NFPA 70.
Label: US: 5A7AL01B728ULT
Filing Type: New Filing
Product Identifier: 728ULT
Equipment Code: AL
Network Address Signal Code: E
Country of Origin: CANADA (CAN)
AC Ringer Equivalent Number: 01B
USOC Jacks: RJ31X
Equipment Description: Control panel for residential burglar and
fire warning systems
Rechargeable Acid/Lead or Gel Cell Backup Battery: 12Vdc, 4Ah/
7Ah; UL/cUL: 12Vdc, 7Ah only
Transformer: Universal, Model No. UB1640W, 16.5Vac (50-60Hz)
20VA minimum (40VA recommended). Do not connect the
transformer to a switch-controlled outlet.
Bell/Siren: UL/cUL Wheelock 46T-12
Aux Power: 450mA (fuseless shutdown at 650mA); UL: 200mA
maximum for 24Hr stand-by
Smoke Detector: 2-wire Hochicki model SLR 835BH-2 (see
page 10 for more information)
Warning: For UL installations, the metallic enclosure must be
grounded to the cold water pipe or to the grounding rod.
UL/cUL: All outputs are Class 2 or power-limited, except for the
battery terminal. The Class 2 or power-limited fire alarm circuits
shall be installed using CL3, CL3R, CL3P or substitute cable
permitted by the National Electrical Code, ANSI/NFPA 70.
Requirements and Guidelines for AUSTEL Installations
Austel-approved installations: use a transformer approved by the
State Electricity commission, such as "Dyen" PA series 15Vac
22VA. With this transformer, do not exceed the following maximum
currents:
- maximum Auxiliary current (including keypads): 300mA
- maximum Bell current: 600mA
Requirements and Guidelines for cUL Installations
When the system controls a fire alarm system, wiring method must
correspond to section 32 of the Canadian Electrical Code.
Look for the cUL mark on the product. Only products bearing this
mark are cUL listed.738 Ultra is not UL listed.
Rechargeable Acid/Lead or Gel Cell Backup Battery: 12Vdc, 4Ah/
7Ah; UL/cUL: 12Vdc, 7Ah only
Transformer: Universal, Model No. UB1640W, 16.5Vac (50-60Hz)
20VA minimum (40VA recommended). Do not connect the
transformer to a switch-controlled outlet.
Bell/Siren: UL/cUL Wheelock 46T-12
Aux Power: 450mA (fuseless shutdown at 650mA); UL: 200mA
maximum for 24Hr stand-by
Smoke Detector: 2-wire Hochicki model SLR 835BH-2 (see
page 10 for more information)
© 2003-2005 Paradox Security Systems Ltd. Esprit and Ultra are
trademarks or registered trademarks of Paradox Security Systems
Ltd. and its affiliates in Canada, the United States and other
countries. All rights reserved. Specifications may change without
prior notice. One or more of the following patents may apply:
6215399, 6111256, 5751803, 5721542, 5287111, 5119069,
5077549, 5920259 5886632. Canadian and international patents
may also apply.