6.11 Report Zone Restore Options
Feature Select Programming ? Address 088; key [BYP]
Default: Zone Restore Codes Transmit on Bell Cut-Off
With the [
BYP
] key "Off", the report codes programmed at addresses 424-447 (see Restore Codes in
section 6.6.4) will only transmit if the zone has returned to normal after bell cut-off (see section 8.11).
With the [
BYP
] key "On", the codes will transmit as soon as the zone returns to normal (zone closure).
Key [BYP] "Off": Report on Bell Cut-Off
Key [BYP] "On": Report on Zone Closure
[ENTER] + Installer Code + [10] [8] [8] + [BYP] On/Off + [ENTER]
6.12 Report Code Disarming Options
Feature Select Programming ? Address 088; key [TRBL]
Default: Disarming Codes Transmit on User Disarming
With the [TRBL] key "OFF", the Disarming Codes programmed at addresses 350-399 (see in
section 6.6.2) will transmit whenever a User disarms the system. With the [TRBL] key "ON", the
control panel will transmit these codes when a User disarms a system in alarm.
Key [TRBL] "Off": Always Report Disarm
Key [TRBL] "On": Report Disarm Only After Alarm
[ENTER] + Installer Code + [10] [8] [8] + [TRBL] On/Off + [ENTER]
Event Reporting

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Esprit 748 express + and is the answer not in the manual?

Paradox Esprit 748 express + Specifications

General IconGeneral
BrandParadox
ModelEsprit 748 express +
CategoryControl Panel
LanguageEnglish

Related product manuals