33
7.13 Keypad Zone 1 Supervision
Feature Select Programming ? Address 090, key [11]
Default: Disabled
When using a keypad defined as keypad zone 1, enable this feature. When enabled, the control
panel will verify the presence of a keypad and the keypad zone. For more information see Keypad
Zone Connections in section 2.8.
Key [11] "Off": Keypad Zone 1 Disabled
Key [11] "On": Keypad Zone 1 Enabled
[ENTER] + Installer Code + [10] [9] [10] + [11] On/Off + [ENTER]
7.14 Keypad Zone 2 Supervision
Feature Select Programming ? Address 090, key [12]
Default: Disabled
When using a keypad defined as keypad zone 2, enable this feature. When enabled, the control
panel will verify for the presence of a keypad and the keypad zone. For more information see
Keypad Zone Connections in section 2.8.
Key [12] "Off": Keypad Zone 2 Disabled
Key [12] "On": Keypad Zone 2 Enabled
[ENTER] + Installer Code + [10] [9] [10] + [12] On/Off + [ENTER]