10.10 Exclude Power Failure From Trouble Display
Feature Select Programming ? Address 090, key [2ND]
Default: Disabled
Excludes the Power Failure, key [2], from the Trouble Display (see section 11.2).
10.11 Audible Trouble Warning
Feature Select Programming ? Address 090, key [9]
Default: Disabled
Trouble conditions will emit an intermittent "beep" on the keypad. To silence the trouble warning,
press the [TRBL] key.
10.12 Power Down Reset
Performing a power down reset will set the installer and master codes to factory default. Values
entered at addresses 008-043, 062-124, 300-527, and all user codes will be erased ([2ND], [2ND]
).
Programmed values for all other addresses do not change. To perform a reset, the installer lock
must be disabled. To perform a power down reset perform the following:
1) Verify installer lock is disabled (see section 3.5)
2) Remove the battery and AC power from the control panel.
3) Set the reset jumper to on by placing a jumper on the reset pins of the control panel.
4) Re-connect the AC and battery power to the control panel.
5) Wait 10 seconds and remove the jumper.
Other Options

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Esprit 748 express + and is the answer not in the manual?

Paradox Esprit 748 express + Specifications

General IconGeneral
BrandParadox
ModelEsprit 748 express +
CategoryControl Panel
LanguageEnglish

Related product manuals