5-6  
The Keypad  
 
650V AC Drive 
Selecting Local or Remote Control 
The drive can operate in one of two ways: 
Remote Control:  Allowing access for application programming using digital and 
analog inputs and outputs 
Local Control:  Providing local control and monitoring of the drive using the 
Keypad  
Local control keys are inactive when Remote Control is selected. 
In Remote Control, the drive uses a remote setpoint. In Local Control, it uses the Local Setpoint 
parameter whose value is adjusted on the MMI. 
Note: 
You can only change between Local and Remote Control when the drive is “stopped”, 
and either 
 or the Local Setpoint is displayed. 
Remote to Local Control: 
Local to Remote Control: 
 
 
 
Note: 
For safety reasons, the drive will not return to Remote Control if this will cause the drive 
to start. Check RUN and JOG inputs are low. 
Changing Direction in Local Control 
When the drive is running in Local Control the direction of rotation of the motor shaft can be 
changed by pressing the following key combinations: 
To change the direction to Forward, press UP and START or UP and STOP. 
To change the direction to Reverse, press DOWN and START or DOWN and STOP. 
It is recommended that if the motor is already turning, choose the key combination that includes 
the START key.  If the motor is stopped then choose the key combination that includes the 
STOP key. 
Hold this key down until
the display shows 
REMOTE
LOCAL
Hold this key down until
the display spells 
Release the key to display
the Local Setpoint
REMOTE
LOCAL
View the Local Setpoint
Hold this key down until
is removed from the display
Release the key to display